Integration Guide
Table Of Contents
- Module Integration Guide
- Preface
- About this Guide
- Introduction
- Manufacturing Process
- Hardware Integration Recommendations
- PCB Layout Rules
- Bring-Up and Testing
- Hardware Test Preparation
- Abbreviations
BRING-UP AND TESTING
FUNCTIONAL VERIFICATION WITH ASSEMBLED MODULE
32 PROPRIETARY MODULE INTEGRATION GUIDE
SEQUANS Communications
5.4.1.2 Troubleshooting
• Excessive current draw
Check all VZM20Q voltage supplies. Confirm that there is no VZM20Q
supply short circuits. Voltage should read according to the nominal
requirement.
• No current draw or current less than expected
a) Check the external power supply wiring
b) Check for dry joint between VZM20Q pin(s) and the power supply
source.
5.4.2 Confirm Module Power-Up Operation (UART1)
An example of the output on UART1 console is provided below (boot in FFH
mode):
[0000000000] RBGerbil 11.5@26553 '5.0.0.0 [26553]'
[0000000004] Reset cause 'EXT'(real 'EXT' ) (bootWDG :
'0') [rawRst '0x00000001']
[0000000011] regConfig 0xEF317ABF@1
[0000000014] Running sector 0x1C040000
[0000000018] boot: Current flash, timeout 10000, proto thp
[0000000023] FFH forced.
[0000000025] boot: Switched to uart1, timeout 60000, proto
at
[0000000031] uart: using uart1 with baudrate 921600
[0000000035] [AT] Info: Forcing baudrate to 115200 for AT
negociation