PRELIMINARY DATA SHEET • SKY66430-11: LTE FOR IoT SYSTEM-in-PACKAGE
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
10 August 26, 2019 • Skyworks Proprietary and Confidential Information • Products and Product Information are Subject to Change Without Notice • 204412F
Electrical and Mechanical Specifications
The absolute maximum ratings of the SKY66430-11 are shown
in Table 2. Recommended operating conditions of the
SKY66430-11 are provided in Table 3. SIP electrical
specifications are shown in Table 4. The electrical specifications
for low-band Tx are provided in Table 5. Table 6 shows the
electrical specifications for mid-band Tx.
Table 7 shows the Rx electrical specifications for
low-band and mid-band RX. Table 8 shows the AUX port
electrical specifications.
Table 2. SKY66430-11 Absolute Maximum Ratings
1
Parameter Symbol Min Typ Max Units
RF input power (AUX Tx/Rx) CW PIN 37.5 dBm
Supply voltages (with RF) VBATT -0.5
TBD V
Operating case temperature TCASE
2
-40 25 +85 °C
Storage temperature TSTG -40 +150 °C
1
Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters
set at or below their nominal value. Exceeding any of the limits listed here may result in permanent damage to the device.
2
T
CASE refers to the temperature of the ground pad on the underside of the package.
ESD HANDLING: Although this device is designed to be as robust as possible, electrostatic discharge (ESD) can damage this device.
This device must be protected at all times from ESD when handling or transporting. Static charges may easily produce
potentials of several kilovolts on the human body or equipment, which can discharge without detection.
Industry-standard ESD handling precautions should be used at all times.
Table 3. SKY66430-11 Recommended Operating Conditions
Parameter Symbol Min Typ Max Units
Supply voltage VBATT 3.1 3.8 5.5 V
Case operating temperature range TRANGE -40 +25 +85
°C