Datasheet
As per 06/2016
11
GmbH
Fault/Error Possible Cause Possible Remedial Action
Motor does not Mechanical blocking Switch off, de-energize and eliminate
rotate blocking
Defective mains voltage Check mains voltage, re-connect
voltage supply
Defective connection Rectify connection, see pin assignment
(Data Sheet)
Motor is too hot Allow motor to cool down/identify
cause of fault
Electronics defect Exchange product
Motor winding interrupted Exchange product
Ambient temperature too Reduce ambient temperature
high if possible
Impeller runs Unbalance of rotating Clean product. If still running untrue
untrue parts after cleaning, exchange product
In the event of further faults, please contact SEPA EUROPE GmbH.
Safety inspection
What requires inspecting? How to check?? Frequency
Casing of protection against Visual inspection Min. ½ yearly
accidental contact
Product for damage Visual inspection Min. ½ yearly
Fixation of product Visual inspection Min. ½ yearly
Fixation of connection cables Visual inspection Min. ½ yearlys
Insulation of wires Visual inspection Min. ½ yearly
i