User guide

Specifications
A–2 700-0098 R006
A.3.1. Advanced Smart-Temp™
A.3.2. Trooper TL Functional Features
A.3.3. Trooper TL Front Cover, Cable Cover
Temperature inside DVR Advanced Smart-Temp…
Below –4°F (–20°C) DVR is not powered, although the drive can still be removed from the
DVR, the heater is on. If the temperature falls below a preset value with
the heater on, the DVR shuts down.
Above 149°F (65°C) Shuts down the DVR to protect the drive from damage.
Time Format 12-hour or 24-hour format
Date Format mm-dd-yyyy, dd-mm-yyyy and yyyy-mm-dd
Camera Title 8 characters
Repeat Record User selectable On/Off
Record Delay-On and Record Delay-Off 0 seconds to 60 minutes
Power Delay-Off 0 minutes to 4 hours
Daily Timers 10
Alarm ALM1 to ALM4 are available.
ALM1 can be achieved via the
ALARM connector on the
DVR.
ALM1 to ALM4 can be achieved via the adapter
harness.
Playback Search Date and Time, Ignition, Alarms, or All Events
Playback Speed Image-by-Image, 1×, 2×, 4×, 8×, 16×, 32×, step
USB Memory Device USB 2.0 compatible
Main Enclosure 18 GA cold rolled steel (CRS), powder coated black paint
Door Lock Industrial cam lock, keyed alike.
Dimensions (H × W × D) 2 516 × 8 316 × 10 18" (59 × 208 × 257 mm).