User`s guide
Configuring the DVR
3–18 700-0058 R001
To change a setting on the sub-menu:
1. Turn the
JOG wheel clockwise or counter clockwise to change the value.
2. Press the
LOCK > button to advance through the fields.
3. Press the
DISPLAY < button to move back through the fields.
The selected menu item is highlighted with a pale blue background.
4. Press the
CLEAR button to reload the default value into a field.
5. To exit the menu, press the
MENU button.
6. Repeat these steps to set the Label and Level. See Table 3-12.
Table 3-12
Signal configuration items
Menu Item Description Values Default
LABEL (1) LT (Left) LT
2 STP (Stop) STP
3 BRK (Brake) BRK
4 WRN (Warning lights) WRN
5 RT (Right) RT
6–10 Signals 6 to 10 are CAN signals and are defined by the user. See “2.12.
CAN Network” on page 2–16.
No default.
LEVEL Indicates the activation level for the signal.
•If
ACTIVE HIGH is selected, 12 VDC
applied to a signal causes the text to be
displayed.
•If
ACTIVE LOW is selected, 0 VDC
applied to a signal causes the text to be
displayed.
•If
CAN is selected, a CAN network
message causes the signal to be
activated.
ACTIVE HIGH, ACTIVE LOW
OR CAN
ACTIVE
HIGH