2.2.8 Application (Compact Fixed Dome Excluded)
The Application setting can be found under this path: System> Application.
The IS-IP290 equips one alarm input and one relay output for cooperating
with alarm system to catch events’ images. Refer to alarm pin definition below to
connect alarm devices to the IS-IP290 if needed.
Alarm
Pin
Definition
Please refer to User’s Manual for Alarm Pin Definition to connect the alarm
devices.
Alarm
Switch
The Administrator can enable or disable the alarm function.
Alarm
Type
Select an alarm type, <Normal close> or <Normal open>, that corresponds with
the alarm application.
Alarm
Output
Define alarm output signal <high> or <low> as the normal alarm output status
according to the current alarm application.
Triggered
Action (Multi-option)
The Administrator can specify alarm actions that will take when the alarm is
triggered. All options are listed as follows:
Enable Alarm Output
Select the item to enable alarm relay output.
IR Cut Filter
Select the item and the camera’s IR cut filter (ICR) will be removed (on)
or blocked (off) when alarm input is triggered.
Note: The IR Function (Refer to IR Function) could not be set as
<Auto> mode if this triggered action is enabled.
Send Message by FTP/E-Mail
The Administrator can select whether to send an alarm message by FTP
and/or E-Mail when an alarm is triggered.