Specifications
Page 64 /148
• Weight 370.5 lb / 168.06 kg (fully-loaded system)
• Mounting Front or center rack mount
Power
Requirements:
DC
• Power Supply 2,600 watts maximum output
• DC Input Voltage –48 to –60 VDC operating range
• Input DC Current 65A at –48 rating
• Output Voltages +48 V at 8 A, +8 V at 6 A, –48 at 60 A
Thermal Output • Thermal Output 9,400 BTU / hour
Environment
• Temperature: 32 to 104 degrees F / 0 to 40 degrees C
• Maximum Altitude: No performance degradation to
10,000 ft / 3,048 m
• Relative Humidity: 5 to 90 percent noncondensing
• Shock: Tested to meet Bellcore Zone 4 earthquake
requirements
Agency
Approvals
Safety
• CSA C22.2 No. 950 * UL 1950
• EN 60950, Safety of Information Technology
Equipment
• EN 60825-1 Safety of Laser Products - Part 1:
Equipment Classification, Requirements and User's
Guide
• EN 60825-2 Safety of Laser Products - Part 2: Safety of
Optical Fibre Communication Systems
EMC
• AS 3548 Class A (Australia)
• EN 55022 Class A emissions (Europe)
• FCC Class A (USA)
• VCCI Class A (Japan)
Immunity
• EN 61000-3-2 Power Line Harmonics
• EN 61000-4-2 ESD
• EN 61000-4-3 Radiated Immunity
• EN 61000-4-4 EFT
• EN 61000-4-5 Surge
• EN 61000-4-6 Low Frequency Common Immunity
• EN 61000-4-11 Voltage Dips and Sags
NEBS
• Designed to meet these standards
• GR-63-Core: NEBS, Physical Protection
• GR-1089-Core: EMC and Electrical Safety for Network
Telecommunications Equipment
• SR-3580 NEBS Criteria Levels (Level 3 Compliance)
Interfaces and Port Density on the M160
M160 Ports per
PIC
PICs per
Chassis
Ports per
Chassis
Ports per
Rack
E1 4 32 128 256
T1 4 32 128 256
E3 4 32 128 256
DS-3 4 32 128 256
ChDS-3 to T1 4 32 128 256
ChOC-12 to DS-3 1 32 32 64
OC-3/STM-1 ATM 4 32 128 256
OC-12/STM-4 ATM 1 32 32 64
OC-3/STM-1 POS 4 32 128 256
OC-12/STM-4 POS 1 32 32 64
OC-48/STM-16 POS 1 32 32 64
OC-192/STM-64 POS 1 8 8 16
FE TX 4 32 128 256
GE SX/LX 1 32 32 64
GE SX/LX (FPC2) 2 32 64 128
OC-12/STM-4 POS (FPC2) 4 32 128 256
OC-48/STM-16 POS (FPC2) 1 32 32 64