Product specifications

Part No. 960-000159R_Rev. 1 © 2013, JCM Global, Corporation
24
April, 2013 Software Guide Sentry® 2.0 Intelligent Bezel
L
AST
F
IVE
B
ANKNOTE
I
NSERTION
I
NDICATOR
The Sentry 2.0 Bezel displays the last five (5) insertions (Banknotes or Tickets)
accepted by the Unit to which it is connected.
Upon Banknote insertion into the Banknote Validator, the Sentry 2.0 Bezel tracks
the elapsed time between the last five (5) Banknote/Ticket insertions. The
“Last
Bill-in Attendant”
screen will display the correct Currency symbol for that inser-
tion, its direction, denomination, and the elapsed time in minutes and seconds
between each Banknote/Ticket inserted.
C
URRENCY
AND
D
ENOMINATION
I
NDICATOR
The Sentry 2.0 Bezel displays the Currency Symbol and Denomination of the last
five (5) Banknotes inserted in the lower left corner of the “Last Bill-in” Screen.
E
LAPSED
T
IME
I
NDICATOR
The Sentry 2.0 Bezel displays the elapsed time since the previous Banknote was
inserted in the lower right corner of the Display. The time units are abbreviated
with
“d” for days, “h” for hours, “m” for minutes, and “s” for seconds.
F
ACE
-
UP
/F
ACE
-
DOWN
I
NDICATOR
The Sentry 2.0 Bezel display indicates the Banknote insertion direction with an
“Arrow” Symbol appearing in the upper right corner of the Display. An upward
facing “Arrow” symbol indicates that the Banknote was inserted face-up.
A Downward facing “Arrow” indicates the Banknote was inserted face-down.
When inserting a Ticket, the last display statement will indicate
"Ticket" where the
denomination value is typically displayed.
If the last Banknote or Ticket inserted is rejected, the
“Last Bill-in” Screen does not
change state.
NOTE: When using the JPL Communication Protocol, verify that the
Face-up or Face-down Icon (located in the upper right corner of the
Sentry 2.0 Display) is present. When using other Communication
Protocols, verify the Face-up or Face-down Icon is NOT PRESENT.
Part No. 960-000159R_Rev. 1 © 2013, JCM Global, Corporation
5
April, 2013 Software Guide Sentry® 2.0 Intelligent Bezel
ABOUT THE SENTRY 2.0 PC CONFIGURATION SOFTWARE
To launch the Sentry 2.0 Download and Configuration Utility Application:
1. From the PC/Laptop’s Windows Desktop, double-click the JCM icon to launch the
Sentry 2.0 PC Configuration Application.
The SENTRY 2.0 User Interface opens in “Player” Mode (default), with the
“Configuration” tab displayed, as shown below.
To view and configure settings on the “Diagnostics” and “Download” tabs
(described on the following pages), click on the desired tab.
NOTE: To install or update the Sentry 2.0 Firmware, see the
procedures for Downloading Software Application Firmware.
NOTE: When the Configuration Utility’s USB connection to the
Sentry 2.0 Unit is successful, the Status Bar at the bottom of the
Sentry 2.0 Configuration Screen displays: “Device: Connected.”
Figure 2 SENTRY 2.0 Configuration Tab (default display)
a
NOTE: To switch from “Player” Mode to “Attendant” Mode or
“Technician” Mode, see Remote Access Device Settings.