Product specifications

Part No. 960-000159R_Rev. 1 © 2013, JCM Global, Corporation
14
Sentry® 2.0 Intelligent Bezel Software Guide April, 2013
C
ASH
B
OX
L
EVELS
When a Sentry 2.0 Bezel is connected to, and powered from, an iVIZION Unit
Banknote Validator using a JPL Protocol, the Cash Box Level is displayed as:
Low < 466 Notes (in a 600-note Cash Box).
Nearly full > 466 Notes, but less than 600 (for a 600-Note Cash Box).
Full = 600 Notes (when using a 600-note Cash Box).
Use the Remote Access Device to view the Cash Box levels.
FIRMWARE VERSION
To view the current Sentry 2.0 Bezel’s Firmware Version:
1. Click the “Diagnostics” Tab.
2. The “Firmware Version” window (Figure 9 a), displays the Firmware Version
installed in the Sentry 2.0 Unit that is currently connected to the Sentry 2.0
Configuration utility via the USB Port.
Figure 9 SENTRY 2.0 View Firmware Version Screen
a
Part No. 960-000159R_Rev. 1 © 2013, JCM Global, Corporation
15
April, 2013 Software Guide Sentry® 2.0 Intelligent Bezel
SET MODE
If the Remote Access Device push button appears to be inoperative, the
Set Mode
radio buttons enable the Sentry 2.0 Bezel to enter the available Operational
Modes. In this event,
Set Mode can help verify whether the Unit’s Sentry 2.0
Firmware is responding, indicating a possible hardware interface problem.
Additionally,
Set Mode can be helpful in the field; for example, a Technician may
have connected a PC to the Sentry 2.0 Unit via a USB Cable, but a Remote Access
Device may not be readily available. In this event, Set Mode can be used to view
the Attendant and Technician Screens’ Show Current Status.
To access the Sentry 2.0 Bezel’s Set Mode options, click the “Diagnostics” Tab.
NOTE: The currently-supported Set Mode options include the Player,
Attendant and Technician Modes (Figure 10 a).
Figure 10 SENTRY 2.0 Set Mode Options Screen
a