User manual

47
Transparent: The alarm is active only while receiving alarm input. The alarm condition is canceled when the
alarm input ceases.
Timed Out: The alarm condition is latched for the amount of time selected in this menu, then it is
automatically silenced and acknowledged. If the alarm input exceeds the duration specified in this menu, the
unit silences and acknowledges the alarm when the alarm input ceases. Select the timeout duration, the range is
from 1 to 250 seconds.
Transparent alarms cannot be silenced and acknowledged. If transparent mode is preferred, but the ability to
silence and acknowledge alarms is desired, select Timed Out and set the Alarm Timeout to two seconds.
Main Menu / Alarms / Enable/Disable
Figure 36. The alarms enable/disable menu
Use this menu to Enable or Disable the alarm inputs.
Select from the following options:
Individual Enable: Allow the user to access the Alarm Enable submenu, and enable or disable alarm
inputs on a per camera basis.
Enable All
Disable All
Rotate the Jog to navigate, and the Shuttle to change the values.
Save changes and exit the menu: Select [OK], then press the Enter button.
Exit the menu without making changes: Press the Menu button, or select [CANCEL], then press the Enter
button.