User manual
StoreSafe Pro II
User Manual
46
Main Menu / Alarms / Input Configuration
Figure 34. Input configuration menu
Configure the alarm inputs as either Normally Open or Normally Closed.Configure inputs as follows.
Normally Open Zero Potential Relay Contact: Configure in menu as Normally Open.
Normally Closed Zero Potential Relay Contact: Configure in menu as Normally Closed
TTL Active High: Configure in menu as Normally Closed.
TTL Active Low: Configure in menu as Normally Open.
Open Collector Active On: Configure in menu as Normally Open.
Open Collector Active Off: Configure in menu as Normally Closed.
Main Menu / Alarms / Alarm Latch
Figure 35. The alarm latch menu
This feature determines how the unit latches alarm conditions.
Selecting from the following options.
Latched: The alarm is activated until it is silenced and acknowledged by the user.