Power-up procedure
Once the system installation is complete, apply power in the following order:
1. Energize the monitors and all of the cameras.
2. Energize StoreSafe Pro II.
Once power is applied to the unit, it will begin its power-up procedure. The unit will begin by displaying the
software version on Monitor-A, and then the unit will be ready for operation.
Check Video Input Quality
Check the picture quality by selecting each camera for full screen display. If the picture quality is poor, check
the following items:
The BNC connections.
The loop-through terminations.
The video levels of incoming signals.
The possibility of ground loops.
Consult the camera’s installation instructions for additional information about proper camera setup.
Check Record And Playback Quality
Record for at least three minutes at the default record rate. Then play back the recording, selecting each camera
for full screen display. Check the playback picture quality.
AUX Port
Figure 4. The accessory PCB
The back panel of the StoreSafe Pro II is equipped with an Aux Port (DB-9 style connector).
Do not attempt to wire directly to the DB-9 connector on the back panel.
Table 7. Power Supply input
Power supply input
Voltage: 12 Volt DC
Power: 60 watt (5 amp)
Connector: 2.1mm barrel, center positive