User manual

StoreSafe Pro II
User Manual
8
Figure 2. The alarm PCB
Active alarm inputs vary by StoreSafe Pro II model. 4 channel units have 4 active alarm inputs, 10 channel
units have 10 active alarm inputs and 16 channel units have 16 active alarm inputs.
Alarm Input
An alarm condition can be activated by devices such as pressure pads, passive infrared detectors, door
switches, or other similar devices.
Alarm Relay Output
The alarm relay output is activated when an alarm condition exists. The alarm output is only active for the
duration of the alarm. Alarm output relay #2 is activated whenever video loss is detected.
Pin 1: Alarm Input 1. Pin 13: Alarm Input 13.
Pin 2: Alarm Input 2. Pin 14 Alarm Input 14.
Pin 3: Alarm Input 3. Pin 15: Alarm Input 15.
Pin 4: Alarm Input 4. Pin 16: Alarm Input 16.
Pin 5: Alarm Input 5. Pin 17: Alarm Output Relay #1.
Pin 6: Alarm Input 6. Pin 18: Ground.
Pin 7: Alarm Input 7. Pin 19: Ground.
Pin 8: Alarm Input 8. Pin 20: Ground.
Pin 9: Alarm Input 9. Pin 21: Alarm Output Relay #1 Common.
Pin 10: Alarm Input 10. Pin 22: Alarm Output Relay #2.
Pin 11: Alarm Input 11. Pin 23: External Alarm Silence and Acknowledge
Input.
Pin 12: Alarm Input 12. Pin 25: Alarm Output Relay #2 Common.