User's Manual

Table Of Contents
Sensys Networks and the Sensys Networks logo are trademarks of Sensys Networks, Inc. All other trademarks are the property of their respective owners.
Information contained herein is believed to be reliable, but Sensys Networks makes no warranties as to its accuracy or completeness.
Copyright © 2017 Sensys Networks, Inc. • ALL RIGHTS RESERVED • CONTENT SUBJECT TO CHANGE
Local Distributor
FlexNode Line Powered Radio (NA)
EMC
FCC: This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
FCC: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment
should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body.
IC: This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device.
IC: This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body.
IC : Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation
est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2)
l’utilisateur de l’appareil doit
accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
IC: Pour se conformer aux exigences de conformité CNR 102 RF exposition, une distance de séparation d'au moins 20 cm doit être
maintenue entre l'antenne de cet appareil ettoutes les personnes.
interfaces
to/from sensors via 802.15.4 PHY radio
to/from repeaters via 802.15.4 PHY radio
to/from access point via 802.15.4 PHY
radio
over-the-air
protocol
Sensys Networks NanoPower (SNP) protocol
(TDMA)
physical layer
protocol
IEEE 802.15.4 PHY
modulation
Direct Sequence Spread Spectrum Oset
Quadrature Phase-Shift Keying (DSSS
O-QPSK)
transmit/receive bit
rate
250 kbps
frequency band
2400 to 2483.5 MHz (ISM unlicensed band)
frequency channels
16
channel bandwidth
2 MHz
internal antenna
type
ceramic patch antenna (behind front face
panel)
internal antenna
eld of view
±60° (azimuth & elevation)
nominal output
power
+3 dBm
spurious emissions
30 - 1000 MHz: < -36 dBm
1 - 12.75 GHz: < -30 dBm
1.8 - 1.9 GHz: < -47 dBm
5.15 - 5.3 GHz: < -47 dBm
typical receive
sensitivity
-101 dBm (PER ≤ 1%)
saturation
(max input level)
≥ 10 dBm
Functional Specications Power, Physical, & Environmental
power supply
12- 24 VDC line powered
(wire 24-12 stranded/solid AWG)
power consumption
0.5 W
dimensions
FLEX-NODE-LPDC:
9.5” x 5.59” x 4.32”
(24.13 cm x 14.19 cm x 10.97 cm)
FLEX-ANT-1: 5.65” x 3.54” x
4.80” (14.4 cm x 9 cm x 12.2 cm)
FLEX-ANT-2: 9.5” x 9.5” x 4.38” (24.10
cm x 24.10 cm x 11.10 cm)
weight
FLEX-NODE-LPDC: 1.25 lbs (0.56 kg)
FLEX-ANT-1: 0.94 lb ( 0.43 kg)
FLEX-ANT-2: 2.2 lb (1 kg)
environmental
designed for weatherproof, outdoor
operation
operating temp
-40ºF to +176ºF / -40ºC to +80ºC
Order Codes Description
FLEX-NODE-LPDC
FFlexNode Line Powered Radio
(NA)
FLEX-ANT-1
Standard External Antenna
FLEX-ANT-2
Long Range External Antenna
Available Products
Compliance