Figure 4.2. SPP radio powered from a traffic controller
Voltages
The APCC uses the following voltages drawn from one of the following sources:
20VDC – 28 VDC (24 VDC nominal) – typically supplied from a nearby traffic
controller cabinet or power pole
10VDC – 16 VDC (12 VDC nominal) – typically supplied from a solar panel
Cabling
Standard Ethernet compatible, outdoor rated, 4-pair CAT5 or better cable is
required. The maximum cable length is 328 feet (100 meters) or 2,000 ft (610
meters) with isolator. The cable should be terminated with RJ45 connectors
according to the TIA/EIA 568-B specification when it is installed.
Collecting Data From the APCC
The APCC automatically collect detection events and, depending on the network
design, forward them to upstream traffic information systems and management
servers via an IP network connection. An on-board Ethernet network interface
facilitates this. In situations where a wired network connection is not available, a
modem supporting either GSM-based or CDMA-based cellular services may be
added.
The following connection models are supported for IP communications:
Connection via a wired network path – for example, bench configuration
prior to installation, field access based on patching a technician's laptop to the
APCC via an Ethernet cable, or an available wide area network connection.