User's Manual

AMR Transmitter Mounting Instructions for Invensys (Equimeter, Rockwell)
models R750, R800
5
Remove index
1.
Remove, with flat or Phillips screwdriver, and properly dispose the two
(2) screws holding the index onto the meter.
2.
Remove the index and carefully clean any debris from it. Inspect for
proper index operation by turning the input shaft and verifying that the
gearing turns freely. Also, inspect the index for any missing or broken
hands. Place the index, or a new index if necessary, on a clean surface
near you for reinstallation later.
3.
If any screws shear off during the cover removal (or were previously
sheared off), the meter will need to be replaced by a qualified utility
representative. Reinstall any index cover screws that were removed and
cap with seals if possible. Enter the appropriate information in the Mint
HHT and skip to the next work order.
4.
With a putty knife, scrap away any gasket material that remained on the
meter when the index cover was removed.