User's Manual
AMR Transmitter Mounting Instructions for Invensys (Equimeter, Rockwell)
models R750, R800
4
AMR Transmitter Installation
Installation Tasks
1. Remove index cover.
2. Remove index from gas meter.
3. Assemble index onto AMR transmitter.
4. Mount AMR transmitter and cover onto gas meter.
5. Initialize AMR transmitter with HHT.
Remove index cover
1. Use flat screwdriver to punch out the seals that cover the two (2) index
cover screws.
2. Remove and properly dispose the two (2) screws holding the index cover
onto meter, with flat screwdriver. If any screws shear off during the
cover removal (or were previously sheared off), the meter will need to be
replaced by a qualified utility representative. Reinstall any index cover
screws that were removed and cap with seals if possible. Enter the
appropriate information in the Mint HHT and skip to the next work
order.
3. Remove the index cover.