User's Manual
AMR Transmitter Mounting Instructions for Schlumberger/Sprague
models S175, S240, S250, MET250, S400 with slant interface
4
AMR Transmitter Installation
Installation Tasks
1. Remove index cover.
2. Remove index from gas meter.
3. Mount AMR transmitter onto gas meter.
4. Assemble index and cover onto AMR transmitter.
5. Initialize AMR transmitter with HHT.
Remove index cover
1. Use small flat screwdriver to punch out the seals that cover two (2) of the
three (3) index cover screws.
2. Remove and properly dispose the three (3) screws holding the index
cover onto meter, with flat screwdriver. If any screws shear off during
the cover removal (or were previously sheared off), the meter will need
to be replaced by a qualified utility representative. Reinstall any index
cover screws that were removed and cap with seals if possible. Enter the
appropriate information in the Mint HHT and skip to the next work
order.
3. Remove the index cover and dispose of properly.