User's Manual

AMR Transmitter Mounting Instructions for American Meter
AC250, AL175, AL250, AL5B, AL225, AL425
4
AMR Transmitter Installation
Installation Tasks
1. Remove index cover.
2. Remove index from gas meter.
3. Mount AMR transmitter onto gas meter.
4. Assemble index and cover onto AMR transmitter.
5. Initialize AMR transmitter with HHT.
Remove index cover
1. Use small flat screwdriver to punch out the seals that cover two (2) of the
four (4) index cover screws.
2. Remove and properly dispose the four (4) screws holding the index cover
onto meter, with flat screwdriver. If two (2) or more screws shear off during
the cover removal (or were previously sheared off), the meter will need to be
replaced by a qualified utility representative. Reinstall any index cover
screws that were removed and cap with seals if possible. Enter the
appropriate information in the Mint HHT and skip to the next work order.
3. Remove the index cover and dispose of properly.