User's Manual
1
Product Description
The FlexNet® wireless transmitter for gas AMR
applications permits offsite meter reading by way of a
fixed base radio network. In addition to solving meter
reading problems such as lockouts, entering unsafe
meter locations, "curbside" reading estimates,
estimated billing, and errors associated with manual
meter reading methods, a fixed network provides
benefits such as daily reads and status alerts.
A significant advantage of the module is its powerful one- Watt transmitter. The long range enabled by the
strong signal and high receiver sensitivity, minimizes the number of base station receivers and provides
optimal coverage at minimal deployment and ongoing costs. FlexNet transmitters are powered by a
replaceable Lithium battery pack, with an expected service life of over 20 years.
The transmitter is enclosed in a durable polycarbonate casing with a clear cover that enables reusing the
original meter index. The module consists of a narrow band transmitter, magnetic sensors, and mechanical
meter interface that includes a shaft with a magnet. A handheld terminal is used to initialize operation. The
module monitors the meter and sends data to the base station receiver network at predefined and
programmable intervals. Transmitter messages contain meter reading data, status and relevant parameters
such as index pressure and the number of dials. Messages are routed to a database, where the data gets
formatted for export to billing, marketing and customer service systems.
Compatible Meters
R175, R200, RT200, RT230, R275, RT275, R315, R250, R310, S110,
S200, 175S, S120, T120, T110 (11-tooth gear)
R415, RT100, RT360 (18-tooth gear)
Sensus (Rockwell, Equimeter,
Invensys)
MR-8, MR-12 (16-tooth gear)
American/Canadian Meter
W75AL, AL175, AC175, AT175, ALC175, AT210, AL225, 5B, AL250,
AR250, AC250, AT250, AM250, AL310, AL350, AT350, AL425, AC630
Actaris (Sprague, Schlumberger)
175, 175WC, 210, 240, 250, 250WC, METRIS 250, 400, 400A
(All slant interface, 3 hole index cover)
Specifications
RF Output
30dBm (1 Watt)
Power Supply
Lithium Thionyl Chloride batteries
with HLC
Range
Urban area (typical) – over
5 miles (8 km)
Battery Life
(Typical)
Over 20 years for daily reads
Over 10 years for hourly reads
Modulation
Proprietary narrow band
Regulatory
Compliance
FCC CFR 47 Part 15, Part 24,
Part 90, and Part 101 Rules
Certified Intrinsic Safety
Certification Measurement
Canada Certification
Data Rate
Up to 8 Kbps
Environmental
-40C to +80C, up to 95% relative
humidity
Frequencies
896-960 MHz, 10,240
channels x 6.25 kHz steps
Alerts
Magnetic tamper Non-reads,
High/Low alerts – via MDM
software
Memory
Non-volatile
Warranty
20 years for battery (with daily
reads) and electronics