User Manual

Table Of Contents
Receiver Section 6-3
SmartPoint Module for the Elster A3 Meter ECMTM40000
The definition of the Auxiliary Status and (reserved) fields can be defined differently for different
Command Types. They are set to 0 unless otherwise specified per command Type.
6.2.3 Set Static Setup
A command to force the device update its static setup:
6.2.4 Set TCXO Correction
A command to force the device update its crystal offset setting:
12 Setup Flags (Reply from Tower Only)
13-31 (reserved)
Byte
(Bits)
Field
0 Repeat Level / Status
1 App Sequence
2 App Code: 7 – Command Message
3 Command Type: 1 – Static Setup
4-7 Buddy Routing Address
8-25 Static Setup Data
26-31 (reserved)
Byte
(Bits)
Field
0 Repeat Level / Status
1 App Sequence
2 App Code: 7 – Command Message
3 Command Type: 2 – Crystal Offset
4-7 Buddy Routing Address
8-9 TCXO Correction
10-31 (reserved)