Setup and Configuration 5-15
SmartPoint Module for the Elster A3 Meter ECMTM40000
5.15 Set Customer Meter Number (0x9D)
Set the 13 byte ASCII Customer meter number. The command has the following format:
The data field in the serial reply message has the 1 byte data status only.
7 – Handheld mPass
Demand Read Ping –
Buddy Disabled
mPass On Air Demand Read Message –
Repeat Level set to 1 to block buddy
8 – Meter Read Mes-
sage
On Air Meter Reading Message (no alarms)
9 – Full Tier Data Meter
Read
Send Meter Reading Message followed by
available Tier Messages
10- Test Meter Read On Air Meter Reading Message (no alarms)
preceded by a meter reading
11 – Single Tier Data
Meter Read
Single Tier Data Message – The byte after the
ping type contains the Tier Information byte for
the desired tier. Note: Does not re-read meter.
14 – Extended Setup On Air Extended Setup Message
15 – Setup On Air Static Setup Message
16 – Binding On Air Binding Message
20 – Single Tier Data
Meter Read, re-read
meter
Single Tier Data Message – The byte after the
ping type contains the Tier Information byte for
the desired tier. Note: Does Re-read meter.
21 – Demand History On Air Demand History Message
23 – LP Meta Data On Air LP Meta Data Message
24 – LP Block Data On Air LP Block Messages - The byte after the
ping type contains the requested block. As
many messages as are required to send a
complete block are sent
25 – LP Block Data –
Single Message
Single On Air LP Block Message - The byte
after the ping type contains the requested
block. The following byte contains the mes-
sage number (0, 1, 2, 3)
Msg Type Length Byte 0 CRC
0x9D 13 Customer Meter Number
Ping Type Device Response