The data field in the reply message has the 1 byte data status only.
5.7 Set TCXO Correction (0x94)
Set TCXO Correction frequency offset. The command has the following format:
The data field in the reply message has the 1 byte data status only.
5.8 Set Latitude/Longitude (0x95)
Set the installation latitude and longitude. The command has the following format:
The data field in the reply message has the 1 byte data status only.
5.9 Set A/D Calibration (0x96)
Set slope and intercept settings for analog to digital conversion . The command has the following format:
The data field in the reply message has the 1 byte data status only.
Msg
Type
Length Bytes 0-1 CRC
0x94 2
TCXO Correc-
tion
Msg
Type
Length Bytes 0-3 Bytes 4-7 CRC
0x95 8 Latitude Longitude
Msg
Type
Length Bytes 0-3 CRC
0x96 4 A/D Conversion