User Manual

Table Of Contents
Setup and Configuration 5-11
SmartPoint Module for the Elster A3 Meter ECMTM40000
The data field in the reply message has the 1 byte data status byte only in the following format:
5.6 Device Static Setup
Set all of the operational parameters of the device. The command has the following format:
The Setup Data field has the following format (all multi-byte fields are sent lesat significant byte first):
Byte
(Bits)
Field
4(0) Status EEROM Write Failed(1)
4(1:6) (Reserved)
4(7) Status ACK(0) / NACK(1)
Msg
Type
Length Bytes 0-17 CRC
0x93 18 Setup Data
Byte
(Bits)
Field
4 (0:2) Meter Sample Rate
4 (3:7) Supervisory Transmit Multiple
5 Base Frequency
6-7 Transmit Channel A
8-9 Transmit Channel B
10-11 Transmit Channel C
12-13 Transmit Channel D
14-15 Receiver Channel
16-17 Boost Mode Channel
18 (0:3) Boost Mode Sub-Channel
18 (4:7) Transmit Channel Mask
19 (0:3) Transmitter Operational Mode
19 (4:6) Receiver Operational Mode
19 (7) Enable Encryption
20-21 Programmer Id
21(7) Disable Compression