2.3 Configuration
This section will describe how the board is configured as shipped, as well as
how it is configured in the field.
2.3.1 Configuration as Shipped
The following table describes the configuration of the endpoint as shipped:
Configuration
Parameter
Default Configuration
Operating Mode
Consumption Only
Interval Period
15 minutes
Administrative
Interval Period
1 hour
Alarm Count
15
Hardware
Revision
1
Firmware
Revision
0.37 (may change prior to shipping)
Scaling Constant
1
Max Pulse Rate
NA
Super Tx
1
# Digits
8
Manufacturer ID
0
Product ID
???
Cumulative Meter
Reading Data
Format
4 bytes, Binary Coded Decimal (first two bytes are always
0). Digits encoded as 0xE indicate digit could not be read.
Device ID Field
RAD-40 encoding of the ASCII-Decimal version of the
LAN Address, padded to 10 digits with zeroes to the left,
padded to 18 characters with spaces on the right.
Transmit
Frequency
917.58MHz +/-10kHz
Default PN Code
x
6
+x
1
+1 (CellNet RFLAN1 Spread Spectrum Channel #1)
Table 2-11 Summary of Configurable Parameters