User's Manual

Sensus Metering Systems-North America Inc. CellNet Water MTU User’s Guide
14
Table 2-8 “Busting” the Endpoint
If the register has been correctly connected to the endpoint, the meter will be
read successfully, and the meter reading will be transmitted to the network 10
times. Thus, following a successful installation of the endpoint, busting the
endpoint will result in 10 blinks of the LED where each blink is associated by an
audible beep. The unit is now activated.
NOTE: In the busting sequence described
above, the meter is read just once prior to
transmission of the first RF packet. The same
meter reading is transmitted 10 times.
If the register has not been correctly connected to the endpoint, the meter will
not be read successfully upon being busted. In this case, the endpoint will not
activate upon closure of the reed switch, and thus will not transmit. Therefore,
until the RF Buster indicates that the unit has been activated, the technician
must assume that the endpoint has not been correctly installed.