Users Manual

PDP User's Guide PDP Collection Software
35
4.2 Collecting Data
Once the settings are configured, you can begin collecting data.
NOTE: Since PDP measures surface reflection which can be affected by the
presence of standing water, do not use the PDP during rain or on wet pavement
as this will produce incorrect values. PDP is intended for use on fresh asphalt,
when it has cooled sufficiently to safely walk on.
Touch the Start button to begin. The number of the next available line is displayed
under Start.
If desired, enter a description of the line (Figure 4-16). Otherwise, leave the
description blank and just touch Apply.
If a description was used for an earlier line, the Last Used Text button will be
enabled (otherwise it will be greyed out). Pressing this button will insert the most
recently used description.
The system will then start collecting data. Collection modes are described below.
Figure 4-16: Entering a description for the line
4.2.1 Profile Mode
In Profile mode, PDP data is collected while the cart is moved. Typically, this is
done to investigate density changes over an area. In most cases, this is done