Specifications

8 INSTALLATION AND SERVICE GUIDE
SpeedDome Ultra III and IV Camera Dome
s
8000-2573-18, REV.
D
Data Cable Requirements
Table 2 shows the data cable requirements for
SensorNet, RS422, and Manchester networks. For
more information about communication protocols
and cable networks, see Communication Protocols
and Cable Networks, 8000-2573-19.
Table 2. Data cable requirements
SensorNet RS422 Manchester
Cable
type
1
unshielded,
twisted pair*
2
shielded,
twisted
pair*
1
shielded
twisted pair**
Wire
gauge
22 AWG 22 AWG 18 AWG
Con-
nection
Non-
polarized
Polarized Polarized
Max.
devices
on line
32 10 3
* Power, data, and video cables can be ordered
separately or within a composite cable that can be
ordered in various lengths. Plenum-rated cables
must be used in indoor ceilings used for environ-
mental air return (called “other air space” in the
National Electrical Code). Order parts through your
distribution network.
Note: If you order cable from an outside source,
wire colors may be different.
** Belden 88760 (plenum), or Belden 8760 cable (non-
plenum) cable is recommended. Plenum-rated
cables must be used in indoor ceilings used for
environmental air return (called “other air space” in
the National Electrical Code). Order cable directly
from Belden by calling 1-800-235-3361.
Install/Removal Tool for
RUIOB Base
The install/removal tool (Figure 9) enables you to
connect or disconnect the housing and eyeball
assembly from the RUIOB base with I/O board,
and to attach/detach skirts and bubbles to a top
hat housing, without the need for a ladder. The tool
attaches to a telescopic pole (purchased
separately). See page 20.
CAUTION: Do not use this tool to connect the
dome the RUPTB base.
Figure 9. RHIRT indoor install/removal tool
Telescopic Pole 08140
by Recreational Water
Products. See page 20
to order.
RHIRT Removal Tool