Specifications

SpeedDome Ultra III and IV Camera Domes
8000-2573-18, Rev. D
INSTALLATION AND SERVICE GUIDE 37
Environmental
Operating Temperature ..........–10° to 50°C (14° to 122°F)
Relative Humidity....................0 to 95% non-condensing
Mechanical
Height .....................................20.8 cm (8")
Diameter .................................12 cm (4.7")
Weight:
Housing and Eyeball ...........1.18 kg (2.6 lbs.)
Base (standard)...................0.09 kg (.20 lbs.)
Base (with I/O board) ..........0.16 kg (.35 lbs.)
Lens and Bubble Densities
Eyeball Lens ...........................f0
Bubbles:
RUCLR (Clear)....................f0
RUSLV (Silver)....................f1.5 to f2
RUSMK (Smoke).................f0.5
RUGLD (Gold).....................f1.5 to f2
Specifications—Outdoor
Housing
Electrical
(combined dome and housing)
Input Voltage.......................... 24 to 30 Vac, 50/60 Hz
UL Class 2 LPS
Design Tolerance................... 20 to 36 Vac, 50/60 Hz
Power Consumption............... 80 W max.
Power On In-Rush Current..... 3 A
Surge Protection .................... Gas discharge tube
impulse rated at 10kA
(8/20µs impulse
discharge current)
Alarm Relay:
Contact Type ...................... Form 1-C
Isolation .............................. 1000 V
Contact Rating.................... 1 A at 30 Vac/dc
Environmental
Operating Temperature.......... –40°C to 50°C
(–40°F to 122°F)
Relative Humidity ................... 0 to 95% non-condensing
Storage Temperature............. –10°C to 50°C
(–14°F to 122°F)
Mechanical
Height..................................... 32.1 cm (12.6")
Diameter ................................ 24.4 cm (9.6")
Weight:
Housing (alone) .................. 2.6 kg (5.7 lbs.)
Housing (with dome) .......... 3.8 kg (8.4 lbs.)