36 INSTALLATION AND SERVICE GUIDE
SpeedDome Ultra III and IV Camera Dome
s
8000-2573-18, REV.
D
Specifications—Indoor Dome
Operational
Pan/Tilt:
Manual Pan/Tilt Speed........1°–100° per second
(scaled to zoom position)
Preset Pan/Tilt Speed .........280° per second
maximum
Pan Travel...........................360° continuous rotation
Tilt Travel ............................>90°
Pan/Tilt Accuracy ................±0.5°
Zoom:
Optical Zoom.......................12X (Ultra III),
16X (Ultra IV)
Digital Zoom........................12X–96X (Ultra III),
16X–128X (Ultra IV)
Zoom Stops.........................Ultra III
1st Stop (selectable):
12X (default)
Max. Zoom (selectable):
24X, 36X, 48X (default),
60X, 72X, 84X, or 96X
Ultra IV
1st Stop (selectable):
16X or 24X (default)
Max. Zoom (selectable):
32X, 48X, 64X (default),
80X, 96X, 112X, or 128X
Zoom/Focus Accuracy ........±0.5%
Auto Synchronization:
Line Locked.........................Remote V-phase
adjustment
Internal ................................Built-in sync generator
Address Range.......................1-255
Programmable Presets:
Number of Presets:
VM16 / ADTT16 .............. 96 with SensorNet 485
VM32 / AD32................... 96 with SensorNet 485
AD2150........................... 64 with Manchester
16 with RS422*
VM96............................... Virtual with RS422 or
SensorNet 485
VM168 / AD168............... 64 with Manchester,
RS422, or SensorNet
16 with RS422*
AD2050........................... 64 with Manchester
16 with RS422*
Acquisition Time................. <1 second to position at
60% of zoom setting
Programmable Patterns ......... 3
Program Storage.................... 256 Kbytes of Flash
memory
Data Storage.......................... 96 Kbytes of SRAM
Menu Languages ................... English, French, German,
Spanish, Italian, and
Portuguese
* Using AD2083-02A
Electrical
Input Voltage.......................... 24–30 Vac, 50/60 Hz
UL Class 2 LPS
Design Tolerance................... 20–36 Vac, 50/60 Hz
Current ................................... 0.85 A max.
Power On In-Rush Current..... 1.5 A
Surge Protection:
Video Output ...................... 100 A
Power Line ......................... 60 V, 1.5 joules, 250 A
RS422 ................................ 5.6 V, 0.1 joules, 40 A
Manchester/
SensorNet 485 ................... Isolated transformer
coupled, 10 kA impulse
rated gas tube
Alarm Inputs ....................... 5.6 V, 0.1 joules, 40 A
Alarms Inputs/Control Outputs:
When no I/O board is used:
Inputs .............................. 1 dry contact/3.5 mA sink
Outputs ........................... 1 open collector driver
@ 12 Vdc, 40 mA
When I/O board is used:
Inputs .............................. 4 dry contacts/3.5 mA sink
Outputs ........................... 4 open collector drivers
@ 12 Vdc, 40 mA