Specifications

SpeedDome Ultra III and IV Camera Domes
8000-2573-18, Rev. D
INSTALLATION AND SERVICE GUIDE 19
11. Set dome address (Figure 17).
Recessed at top of housing and eyeball
assembly are three rotary address switches.
Address range is from 001 to 255, except for
Manchester, which is 01 to 64.
Set switches from most significant bit (MSB)
to least significant bit (LSB). For example:
For address 166, set SW3 to 1, SW2 to 6,
and SW1 to 6.
Figure 17. Setting address switches
090909
MSB
LSB
SW3
SW1SW2
12. Connect housing and eyeball assembly to base
(Figure 18).
a. Align dimple on cap of dome with rib on
mounting base.
b. Mate housing and eyeball assembly to base
and turn it clockwise until you hear a click.
13. Wait a few seconds for dome to begin its
homing routine. Homing routine indicates that
address was placed into dome memory and
that dome is ready for programming.
Figure 18. Connecting housing and eyeball
assembly to base
L
A
T
C
H