Specifications

18 INSTALLATION AND SERVICE GUIDE
SpeedDome Ultra III and IV Camera Dome
s
8000-2573-18, REV.
D
4. Connect alarm output cable, if used,
to P3 connector.
Pin Color Designation
1 12Vdc (100mA max.)
2 12Vdc (100mA max.)
3 Output P0 (40mA sync. max.)
4 Output P1 (40mA sync. max.)
5 Output P2 (40mA sync. max.)
6 Output P3 (40mA sync. max.)
7 — Ground
8 — Ground
5. Connect alarm input cable, if used,
to P4 connector.
Pin Color Designation
1 Alarm 3 input (3.5mA sink)
2 Alarm 2 input (3.5mA sink)
3 Alarm 1 input (3.5mA sink)
4 Alarm 0 input (3.5mA sink)
5 — Ground
6 — Ground
6. Connect power to P7 connector.
Pin Color Designation
1 Black 24 Vac
2 Red Ground
3 White 24 Vac
8. Reattach I/O board.
9. Connect power to base.
10. Check LEDs on I/O board to verify power and
data are reaching dome (Figure 16).
a. Observe green (ac power) and yellow
(comm.) LEDs. Green LED glows steadily
and yellow LED glows steadily (RS422,
Manchester) or blinks (SensorNet).
b. For RS422, press and hold data test switch
SW1 and observe nearby red and green
LEDs; they indicate the following:
Constant green,
Blinking red
RS422 line correctly
wired.
Constant green,
No red
RS422 “Data In –”
shorted to ground.
Constant red,
Blinking green
“Data In +/ –” wires
reversed.
Blinking red,
Green off
“Data In +” shorted to
ground.
Both LEDs off “Data In +/ –” wires
shorted or open.
Figure 16. Test switch/LEDs on I/O board
Comm. LED
Power LED
RS422 Test
Pushbutton
SW1