Specifications
SpeedDome Ultra III and IV Camera Domes 
8000-2573-18, Rev. D 
  INSTALLATION AND SERVICE GUIDE  17
Connecting to RUIOB 
Mounting Base 
This procedure explains how to connect the 
housing and eyeball assembly to an RUIOB 
mounting base. 
CAUTION: The maximum length of cable allowed 
between the Class 2 LPS (low voltage) ac source, 
such as a J-box, and the dome is 250m (820'). 
!
WARNING! 
Ensure that ac power and electrical 
signals are off during wire connections! 
Referring to Figure 15: 
CAUTION: Detach and discard cable clamp 
if I/O board has one. If not removed, clamp can 
damage 9-pin connector in housing and eyeball 
assembly when you attempt to connect it to base. 
1.  Set data communications jumper JW1. If data 
lines continue to another dome, set JW1 across 
pins 1–2 (unterminated). Otherwise, set JW1 
across pins 2–3 (terminated). 
2.  Connect video cable to BNC 
connector P8 on I/O board. 
3.  Connect Manchester, RS422, or SensorNet 
485 data wires to connector P1. 
Manchester data connections (Ultra IV only). 
Order data cable 88760 (plenum) or 8760 
(non-plenum) from Belden by calling 
1-800-235-3361. 
Pin Color  Designation 
1-4 — Not used. 
5 Black Manchester (+) 
6 White Manchester (–) 
RS422 data connections  
Pin Color Designation 
1  Orange  RS422 Data In High (+) 
2  Green  RS422 Data In Low (–) 
3  Yellow  RS422 Data Out High (+) 
4  Brown  RS422 Data Out Low (–) 
5-6 — Not used. 
SensorNet data connections 
Pin Color  Designation 
1-4 — Not used. 
5 Orange SensorNet (unshielded) 
6 Yellow SensorNet (unshielded) 
Figure 15. Electrical connections 
1
P1
P4
P3
P8
P7
JW1
I/O BOARD
JW1 Terminations
FUNCTION
Terminated
Unterminated
PINS
1-2
2-3
Pin 1
Pin 1
Pin 1
Pin 1