Specifications

14 INSTALLATION AND SERVICE GUIDE
SpeedDome Ultra III and IV Camera Dome
s
8000-2573-18, REV.
D
3. WITH POWER OFF, connect video cable
(Figure 12).
a. Connect BNC of video micro coax cable
6003-0131-01 to BNC of video cable.
b. Feed cable through access hole in base.
c. Press micro coax connector into mating
receptacle in top of housing and eyeball
assembly. A firm snap indicates a tight
connection.
4. Set data communications jumper JW1 (Figure
12).
If data lines continue to another dome, set JW1
across pins 1–2 (unterminated). Otherwise, set
JW1 across pins 2–3 (terminated).
You may need a small slotted screwdriver to
gently pry jumper loose. Be careful not to
damage underlying PC board.
Figure 12. Video cable connection and
termination jumper location
5. Connect 9-pin plug (data and power) to 9-pin
receptacle (Figure 13).
CAUTION: DO NOT connect 9-pin plug unless
you have performed step 3 first!
a. Feed cables through access hole in base.
b. Connect data and power wires to 9-pin plug
(refer to charts below).
c. Insert plug into mating receptacle in top of
housing and eyeball assembly.
Manchester data and power connections
(Ultra IV only). Order data cable 88760
(plenum) or 8760 (non-plenum) from Belden by
calling 1-800-235-3361.
Pin Color Designation
1 White Manchester (–)
2 Black Manchester (+)
3 Black 24Vac
4 Red Ground
5 White 24vac
6-9 — Not used.
RS422 data and power connections
Pin Color Designation
1-2 — Not used.
3 Black 24Vac
4 Red Ground
5 White 24vac
6 Orange RS422 Data In High (+)
7 Green RS422 Data In Low (–)
8 Yellow RS422 Data Out High (+)
9 Brown RS422 Data Out Low (–)
SensorNet data and power connections
Pin Color Designation
1 Orange SensorNet (unshielded)
2 Yellow SensorNet (unshielded)
3 Black 24Vac
4 Red Ground
5 White 24vac
6-9 — Not used.
Termination
Jumper JW1
Micro
Coax
Cable