Specifications
14  INSTALLATION AND SERVICE GUIDE 
SpeedDome Ultra III and IV Camera Dome
s
8000-2573-18, REV. 
D
3.  WITH POWER OFF, connect video cable 
(Figure 12). 
a.  Connect BNC of video micro coax cable 
6003-0131-01 to BNC of video cable. 
b.  Feed cable through access hole in base. 
c.  Press micro coax connector into mating 
receptacle in top of housing and eyeball 
assembly. A firm snap indicates a tight 
connection. 
4.  Set data communications jumper JW1 (Figure 
12). 
  If data lines continue to another dome, set JW1 
across pins 1–2 (unterminated). Otherwise, set 
JW1 across pins 2–3 (terminated). 
  You may need a small slotted screwdriver to 
gently pry jumper loose. Be careful not to 
damage underlying PC board. 
Figure 12. Video cable connection and 
termination jumper location 
5.  Connect 9-pin plug (data and power) to 9-pin 
receptacle (Figure 13). 
  CAUTION: DO NOT connect 9-pin plug unless 
you have performed step 3 first! 
a.  Feed cables through access hole in base. 
b.  Connect data and power wires to 9-pin plug 
(refer to charts below). 
c.  Insert plug into mating receptacle in top of 
housing and eyeball assembly. 
Manchester data and power connections 
(Ultra IV only). Order data cable 88760 
(plenum) or 8760 (non-plenum) from Belden by 
calling 1-800-235-3361. 
Pin Color Designation 
1 White Manchester (–) 
2 Black Manchester (+) 
3 Black 24Vac 
4 Red Ground 
5 White 24vac 
6-9 — Not used. 
RS422 data and power connections 
Pin Color Designation 
1-2 — Not used. 
3 Black 24Vac 
4 Red Ground 
5 White 24vac 
6  Orange  RS422 Data In High (+) 
7  Green  RS422 Data In Low (–) 
8  Yellow  RS422 Data Out High (+) 
9  Brown  RS422 Data Out Low (–) 
SensorNet data and power connections 
Pin Color Designation 
1 Orange SensorNet (unshielded) 
2 Yellow SensorNet (unshielded) 
3 Black 24Vac 
4 Red Ground 
5 White 24vac 
6-9 — Not used. 
Termination 
Jumper JW1 
Micro 
Coax 
Cable 