Connecting to RUPTB 
Mounting Base 
This procedure explains how to connect the 
housing and eyeball assembly to a RUPTB base. 
CAUTION: The maximum length of cable allowed 
between the Class 2 LPS (low voltage) ac source, 
such as a J-box, and the dome is 250m (820'). 
!
WARNING! 
Ensure that ac power and electrical 
signals are off during wire connections! 
1.  Set dome address (Figure 10). 
  Recessed at top of housing and eyeball 
assembly are three rotary address switches. 
Address range is from 001 to 255, except for 
Manchester, which is 01 to 64. 
  Set switches from most significant bit (MSB) 
to least significant bit (LSB). For example: 
For address 166, set SW3 to 1, SW2 to 6, 
and SW1 to 6. 
Figure 10. Setting address switches 
090909
MSB
LSB
SW3
SW1SW2
2.  Attach safety lanyard to cap on housing 
and eyeball assembly (Figure 11). Use M3 x 6 
screw supplied with lanyard. 
Figure 11. Attaching safety lanyard 
Only use this 
location to secure 
lanyard. 