Specifications
38 Video Multiplexer with Video Motion Detection
Alarm Counter
The multiplexer counts the number of mechanical alarm events
that occur at each camera input. The alarm counter maintains a
total count for each camera until the alarm counter is cleared.
Motion alarms are counted for any cameras with the ALRM option
ON. If during motion setup you set the ALRM option to AND, an
alarm is generated only when motion and a mechanical alarm
happen at the same time for that camera. If the menu option for
VIDEO LOSS ALARM is set ON, video loss alarms will also be
included in the alarm count. If set to OFF, video loss will not be
counted as an alarm.
To view these totals during normal operation, press Function+left
arrow. The count will update if an alarm occurs with the alarm
counter on screen. The multiplexer displays the alarm count for
each camera input and the time and date the count was last cleared.
Press Live to exit the alarm counter. The multiplexer removes the
alarm counter from the screen and resumes normal operation.
Alarm counts are NOT cleared and counting alarms continues.
Press Call to clear the alarm counter. The multiplexer resets the
alarm counter (all counts return to 000) and updates the ALARM
COUNT SINCE date and time. Alarm counting begins immediately.
Alarm counters stop at 999. That count remains until cleared.
Figure 9 Alarm Counter