Specifications
22 Video Multiplexer with Video Motion Detection
Menu 7 Camera Titles
Menu 7 allows you to assign a title to each camera input. It also
provides access to the MOTION SETUP SCREENS described below.
Initially each title is the cameras number. To change a title, use
the arrow buttons to position the flashing highlight and select
characters. A title can contain up to 10 characters selected from
the following:
09 AZ _(represents a space) / : = - + .(period)
When you are finished setting a title, do one of the following:
press Function to display the DAY MOTION SETUP SCREEN
(described below) for the current camera.
Menu 5 Alarm Duration
Menu 5 allows you to set the minimum multiplexer alarm time.
The ALARM DURATION setting determines how many seconds
the multiplexer remains in the alarm state after an alarm event
occurs.
Set the ALARM DURATION time using the up and down arrow
buttons. You may use any setting between 2 and 999 seconds.
The default ALARM DURATION setting is 4 seconds.
When finished, press the Zoom button to go to menu 6 or
Function+Zoom to save all changes and leave the setup system.
Menu 6 Global Dwell
The GLOBAL DWELL setting determines the rate at which the mul-
tiplexer sequences cameras on the main monitor (either full screen
or in the lower right window) when Sequence is selected. It also
determines the rate at which the call monitor switches cameras
during multiple alarm events.
Set the GLOBAL DWELL time in seconds using the up and down
arrow buttons. You may enter any setting between 1 and 99
seconds. This setting applies to all cameras.
NOTE: The GLOBAL DWELL setting affects on-screen cam-
era display only. It does NOT affect the rate at which
the multiplexer sends images to the VCR.
The default GLOBAL DWELL time is 2 seconds.
When finished, press the Zoom button to go to menu 7 or
Function+Zoom to save all changes and leave the menu system.