Specifications
8 Video Multiplexer with Video Motion Detection
Figure 6 Rear Panel Connectors (16-camera color model shown)
THE REAR PANEL
1. gnd (ground) Use this ground post when connecting
contact or TTL/CMOS compatible alarm devices. See Alarms
for details.
2. power This 2.1 mm pin jack accepts the multiplexer power
module plug or other center positive source of 12 VDC at 1.5
amperes.
3. remote in This RJ11 connector allows remote control of
the multiplexer using an optional remote control panel. If
daisychaining either additional remote panels or multiplexers,
remote out of the first unit is connected to remote in of the
next unit.
4. remote out This RJ11 connector allows daisychaining to
another multiplexer. Up to 16 multiplexers can be connected
to a remote panel, but only one multiplexer at a time can be
addressed and controlled by the remote control panel.
5. alarms This DB37-S connector allows alarm activation via
contact closure or TTL/CMOS alarm inputs (up to 16). It
includes the alarm hold input and alarm output relay contacts.
There are also 16 motion alarm outputs, and an Autodetect
VCR Speed feature which changes the rate the multiplexer
sends images to match the VCR recording speed.
6. s-vhs out This S-type connector provides an S-Video signal
to an S-VHS video recorder (color models only).
7. s-vhs in This S-type connector accepts the S-Video
playback signal from an S-VHS video recorder (color models
only).