Specifications

38 Multivision® Pro Installation and Operation Manual
Alarm Counter
The multiplexer counts the number of mechanical alarm events
that occur at each camera input. The ALARM COUNTER
maintains a total count for each camera until the ALARM
COUNT is cleared.
Motion alarms are counted for any cameras with the ALRM
option ON. If during motion setup you set the ALRM option
to AND, an alarm is generated only when motion and a
mechanical alarm happen at the same time for that camera. If
the menu option for VIDEO LOSS ALARM is set ON, video
loss alarms are included in the ALARM COUNT. If set to OFF,
video loss is not counted as an alarm.
To view these totals during normal operation, press
function+left arrow. The count updates if an alarm occurs
with the alarm counter on screen. The multiplexer displays
the alarm count for each camera input and the time and date
the count was last cleared.
Press live to exit the ALARM COUNTER. The multiplexer
removes the ALARM COUNT from the screen and resumes
normal operation. Alarm counts are NOT cleared and alarm
counting continues.
Press call to clear the ALARM COUNTER. The multiplexer
resets the ALARM COUNT (all counts return to 000) and
updates the ALARM COUNT SINCE date and time. Counting
alarms begins immediately.
Alarm counting stops at 999. That count remains until cleared.
Figure 9 — Alarm Counter