Specifications
Chapter 4 — Setup 21
Pass-Thru Extrnl Alrms
This option reduces the shakiness and jitter associated with
high resolution compressed multicamera images.
ON — Uses the special filtering circuit when the
multiplexer displays a multicamera image on the main
monitor.
OFF — Turns off the special filtering circuit.
The default IMAGE TENDERIZER setting is ON.
When finished, press the zoom button to go to menu 4 or
press function+zoom to save all changes and leave the setup
system.
Menu 4 — VCR Record Time
Menu 4 allows you to enter the VCR’s normal and alarm re-
cording speeds. With autodetect VCR speed, these settings are
used if that signal is lost. Use the up and down arrow buttons
to set each speed as follows:
VCR RECORD TIME — The VCR’s normal (nonalarm)
operating speed (2—999 hours).
The default VCR RECORD TIME is 024 HRS.
VCR ALARM RECORD TIME — The VCR’s recording speed
for alarms (2—999 hours).
The default VCR ALARM RECORD TIME is 002 HRS.
NOTE: If the multiplexer alarm output is not connected to
the VCR’s alarm input, the VCR RECORD TIME and
the VCR ALARM RECORD TIME should be set to
the same value.
When finished, press the zoom button to go to menu 5 or
function+zoom to save all changes and leave the setup system.
This menu option lets you loop (pass-thru) the external alarm
inputs to the alarm outputs.
YES — Alarm outputs represent all alarms for a particu-
lar camera; motion alarms, mechanical alarms and video
loss alarms.
NO — Alarm outputs are for motion alarms only. Exter-
nal alarms are not included (not passed-thru).
The default PASS-THRU EXTRNL ALRMS setting is YES.
Image Tenderizer