Specifications
10 Multivision® Pro Installation and Operation Manual
Chapter 3 — Installation
Select a location for the product that is clean, dry and has AC
power. Find an environment where temperature and humid-
ity extremes do not exceed product specifications (see Appen-
dix D — Technical Specifications). Failure to do so can result in
equipment failure and loss of warranty protection.
REQUIRED
CONNECTIONS
Connect the video output from a camera or other composite
video source to each cam in. Multiplexer camera input im-
pedance termination is selectable for each camera using the
back panel switches between the rows of BNC connectors. If
looping through to other equipment, set the switch to
∞∞
∞∞
∞.
Cameras 1–16
Main Mon
Connect main mon to the video input of an NTSC/EIA
(PAL/CCIR) compatible video monitor. This monitor displays
selected live or recorded cameras in any available format. This
output must be terminated.
Power
Connect power to the multiplexer power module or other cen-
ter positive source of 12 VDC at 1.5 Amperes.
OPTIONAL
CONNECTIONS
Call Mon
Connect call mon output to the video input of an NTSC/EIA
(PAL/CCIR) compatible video monitor. This monitor displays
the selected or alarm camera in the full screen format. This
output must be terminated.
VCR In
NOTE: Do NOT connect both vcr in and s-vhs in at the
same time. The multiplexer will not function
properly.
Connect vcr in to the composite video output (play) of an
NTSC/EIA (PAL/CCIR) compatible VCR. This input is
terminated.