Type Syntax Response Example
<Assigned_eDRX_cycle>[,
<Assigned_paging_time_window>]]]
7.14.3Defined values
Parameter Type Description
<mode> Number Indication to disable or enable the use of eDRX in the UE. Allowed values:
0 (default and factory-programmed value): use of eDRX disabled
1: use of eDRX enabled
2: enable the use of eDRX and enable the +CEDRXP URC
3: disable the use of eDRX and reset all other parameters for eDRX to factory-
programmed values
<AcT_type> Number Indicates the type of access technology:
2: GPRS/eGPRS
4: E-UTRAN (WB-S1 mode)
5: E-UTRAN (NB-S1 mode)
Allowed values:
SARA-R410M-52B / SARA-R410M-63B / SARA-R410M-73B - 4
SARA-R410M-02B / SARA-R410M-83B - 4, 5
SARA-R412M - 2, 4, 5
SARA-N4 - 5
<Requested_eDRX_
cycle>
String See <Requested_eDRX_cycle>.
<Assigned_eDRX_
cycle>
String See <Assigned_eDRX_cycle>.
<Requested_paging_
time_window>
String See <Requested_paging_time_window>.
<Assigned_paging_
time_window>
String See <Assigned_paging_time_window>.
7.14.4Notes
SARA-R4
The +CEDRXP URC enablement by means of the AT+CEDRXS=2,<AcT_type> commands is not stored in
NVM. Issue AT+CEDRXS=2,<AcT_type> to enable the +CEDRXP URC after each power cycle.
SARA-R410M / SARA-R412M
<mode>=3 is not supported. To reset all the eDRX parameters to factory-programmed values (see
Mobile Network Operator profiles), follow the procedure described in the +UMNOPROF AT command
description.
The <Requested_paging_time_window> parameter is not supported in the read command and in the
test command. Use the +CEDRXP URC or the +CEDRXRDP command to retrieve the <Requested_
eDRX_cycle>, the <Assigned_eDRX_cycle_value> and the <Assigned_paging_time_window>.
SARA-R410M-02B / SARA-R410M-52B / SARA-R412M
The <Requested_paging_time_window> parameter cannot be set by means of the set command.
SARA-N4
The +CEDRXP URC enablement by means of the AT+CEDRXS=2,<AcT_type> commands is not stored in
NVM. Issue AT+CEDRXS=2,<AcT_type> to enable the +CEDRXP URC after each power cycle.
<mode>=3 is not supported. To reset all the eDRX parameters to factory-programmed values (see Mobile
Network Operator profiles), follow the procedure described in the +UMNOPROF AT command description.
The <Requested_paging_time_window> parameter is not supported in the read command and in the
test command. Use the +CEDRXP URC or the +CEDRXRDP command to retrieve the <Requested_eDRX_
cycle>, the <Assigned_eDRX_cycle_value> and the <Assigned_paging_time_window>.
The <Requested_paging_time_window> parameter cannot be set by means of the set command.
SARA-R4 / SARA-N4
The <mode> and <AcT_type> parameters are not optional in set command.