User Manual

Table Of Contents
SARA-R4 series-AT commands manual
UBX-17003787 - R16
7Network service
Page 59 of 401
7.11.2Syntax
Type Syntax Response Example
Read AT+VZWRSRP? +VZWRSRP:
[<cellID1>,<EARFCN1>,<RSRP1>[,
<cellID2>,<EARFCN2>,<RSRP2>[,
...]]]
OK
+VZWRSRP:
000,2175,"-61.00"
OK
7.11.3Defined values
Parameter Type Description
<cellIDn> Number nth cell physical cell identifier in "xxx" format. The range goes from 0 to 503.
<EARFCNn> Number nth cell EARFCN in decimal format. The range goes from 0 to 65535.
<RSRPn> String nth cell RSRP value in dBm/15 kHz where the format is "-XX.XX".
7.11.4Notes
SARA-R4 / SARA-N4
If the current MNO profile is not set to Verizon (see the +UMNOPROF AT command, <MNO>=3) and the
command is issued, the module returns an error result code.
7.12Read RSRQ values +VZWRSRQ
+VZWRSRQ
SARA-R404M SARA-R410M-01B SARA-R410M-02B SARA-R410M-52BModules
SARA-N4
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full No No No - +CME Error
7.12.1Description
Returns the RSRQ (Reference Signal Received Quality) values for all the LTE cells which the module is
measuring.
7.12.2Syntax
Type Syntax Response Example
Read AT+VZWRSRQ? +VZWRSRQ:
[<cellID1>,<EARFCN1>,<RSRQ1>[,
<cellID2>,<EARFCN2>,<RSRQ2>[,
...]]]
OK
+VZWRSRQ:
000,2175,"-11.00"
OK
7.12.3Defined values
Parameter Type Description
<cellID> Number nth cell physical cell identifier in "xxx" format. The range goes from 0 to 503.
<EARFCN> Number See <EARFCN>.
<RSRP> String nth cell RSRP value in dBm/15 kHz where the format is "-XX.XX".
7.12.4Notes
SARA-R4 / SARA-N4
If the current MNO profile is not set to Verizon (see the +UMNOPROF AT command, <MNO>=3) and the
command is issued, the module returns an error result code.