User Manual

Table Of Contents
SARA-R4 series-AT commands manual
UBX-17003787 - R16
7Network service
Page 47 of 401
7.5.2Syntax
Type Syntax Response Example
Set AT+COPS=[<mode>[,
<format>[,<oper>[,
<AcT>]]]]
OK AT+COPS=0,0
OK
Read AT+COPS? +COPS: <mode>[,<format>,<oper>[,
<AcT>]]
OK
+COPS: 0,0,"vodafone IT"
OK
Test AT+COPS=? +COPS: [(<stat>, long <oper>, short
<oper>, numeric <oper>[,<AcT>])[,
(<stat>, long <oper>, short <oper>,
numeric <oper>[,<AcT>]),[...]]],(list of
supported <mode>s),(list of supported
<format>s)
OK
+COPS: (2,"vodafone IT","voda IT","22210
"),(1,"SI vodafone","vodafone SI","29340
"),(1,"I WIND","I WIND","22288"),(1,"I TIM",
"TIM","22201"),(1,"MOBITEL","MOBITEL",
"29341"),,(0-4),(0-2)
OK
7.5.3Defined values
Parameter Type Description
<mode> Number Is used to chose whether the network selection is automatically done by the MT or is
forced by this command to the operator <oper> given in the format <format>:
0 (default value and factory-programmed value): automatic (<oper> field is ignored)
1: manual
2: deregister from network
3: set only <format>
4: manual/automatic
<format> Number
0 (factory-programmed value): long alphanumeric <oper>
1: short format alphanumeric <oper>
2: numeric <oper>
<oper> String Given in format <format> this field may be up to 24 characters long for long
alphanumeric format, up to 10 characters for short alphanumeric format and 5 or
6 characters long for numeric format (MCC/MNC codes). The factory-programmed
value is FFFF (undefined).
<stat> Number
0: unknown
1: available
2: current
3: forbidden
<AcT> Number Indicates the radio access technology:
0: GSM
3: GSM/GPRS with EDGE availability
7: LTE
8: EC-GSM-IoT (A/Gb mode)
9: E-UTRAN (NB-S1 mode)
Allowed values:
SARA-R404M / SARA-R410M-63B / SARA-R410M-73B - 7
SARA-R410M-01B - 8, 9
SARA-R410M-02B / SARA-R410M-52B / SARA-R410M-83B - 7, 9
SARA-R412M - 0, 3, 7, 8, 9
SARA-N4 - 9
SARA-R410M-02B
On SARA-R410M-02B-00 the allowed radio access technology are: 8, 9.
7.5.4Notes
SARA-R4 / SARA-N4
The command setting is not stored in the personal profile.
The set command is abortable, the test command cannot be aborted in the same line.
<format> and <oper> parameters are optional only if the <mode> parameter is set to 0, 2 or 3.