User Manual

Table Of Contents
SARA-R4 series-AT commands manual
UBX-17003787 - R16
5Mobile equipment control and status
Page 30 of 401
5Mobile equipment control and status
5.1Phone activity status +CPAS
+CPAS
Modules All products
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full No No No - +CME Error
5.1.1Description
Returns the activity status <pas> of the MT.
5.1.2Syntax
Type Syntax Response Example
Action AT+CPAS +CPAS: <pas>
OK
+CPAS: 0
OK
Test AT+CPAS=? +CPAS: (list of supported <pas>s)
OK
+CPAS: (0-5)
OK
5.1.3Defined values
Parameter Type Description
<pas> Number MT activity status:
0: ready (MT allows commands from DTE)
1: unavailable (MT does not allow commands from DTE)
2: unknown (MT is not guaranteed to respond to instructions)
3: ringing (MT is ready for commands from DTE, but the ringer is active)
4: call in progress (MT is ready for commands from DTE, but a call is in progress,
e.g. call active, hold, disconnecting)
5: asleep (ME is unable to process commands from DTE because it is in a low
functionality state)
Allowed values:
SARA-R4 / SARA-N4 - 0, 3, 4
5.2Module switch off +CPWROFF
+CPWROFF
Modules All products
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full No No No < 40 s +CME Error
5.2.1Description
Switches off the MT. During shut-down current settings are saved in module's non-volatile memory.
Using this command can result in the following command line being ignored.
See the corresponding System Integration Manual for the timing and the electrical details of the module
power-off sequence via the +CPWROFF command.
SARA-R4
The +UCPWROFF URC notifies that the module power-off is in progress. For more details on the module
power-off procedure, see the SARA-R4 series system integration manual [152].