User Manual

Table Of Contents
SARA-R4 series-AT commands manual
UBX-17003787 - R16
23Positioning
Page 291 of 401
Parameter Type Description
4: Galileo
8: BeiDou
16: IMES
32: QZSS
64: GLONASS
<Reserved1> Number 0 (reserved value)
<Reserved2> Number 0 (reserved value)
23.4.4.4Notes
To enable SBAS system opportunely configure both <SBAS> and <GNSS_systems> parameters.
If a parameter is omitted, the current set value is kept.
For more details on parameter description see the corresponding u-blox-GNSS receiver description.
23.4.5Configure cellular location sensor (CellLocate
®
) +ULOCCELL
+ULOCCELL
Modules SARA-R410M-02B SARA-R410M-52B SARA-R410M-63B SARA-R410M-73B SARA-R410M-83B
SARA-R412M
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full No NVM No - +CME Error
23.4.5.1Description
Configures the Cellular location sensor (CellLocate
®
) used with the +ULOC command.
This command influences the amount of data exchanged with the server.
23.4.5.2Syntax
Type Syntax Response Example
Set AT+ULOCCELL=<scan_mode>[,
<reserved1>[,<reserved2>[,
<reserved3>[,<reserved4>[,
<reserved5>]]]]]
OK AT+ULOCCELL=0
OK
Read AT+ULOCCELL? +ULOCCELL: <scan_mode>,
<reserved1>,<reserved2>,
<reserved3>,<reserved4>,
<reserved5>
OK
+ULOCCELL: 0,0,"","",0,0
OK
Test AT+ULOCCELL=? +ULOCCELL: (list of supported
<scan_mode>s),(list of supported
<reserved1>),(list of supported
<reserved2>),(list of supported
<reserved3>),(list of supported
<reserved4>),(list of supported
<reserved5>)
OK
+ULOCCELL: (0-1),(0),"","",(0),(0)
OK
23.4.5.3Defined values
Parameter Type Description
<scan_mode> Number Network scan mode:
0 (factory-programmed value): normal
1: deep scan
<reserved1> Number RFU
<reserved2> String RFU
<reserved3> String "" (reserved value)
<reserved4> Number 0 (reserved value)
<reserved5> Number 0 (reserved value)