User Manual

Table Of Contents
SARA-R4 series-AT commands manual
UBX-17003787 - R16
10V24 control and V25ter
Page 116 of 401
10.20.3Defined values
Parameter Type Description
<value> Number
0 (default and the factory-programmed value): DCE transmits result codes
1: Result codes are suppressed and not transmitted
10.21DCE response format V
V
Modules All products
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full No No No - +CME Error
10.21.1Description
Control the contents of the header and trailer transmitted with result codes and information text responses.
It also determines whether the result code is transmitted in a numeric form or an alphabetic (or verbose) form.
The information text response is not affected by this setting. See Information text responses and result codes
for description of the result code formats.
10.21.2Syntax
Type Syntax Response Example
Set ATV[<value>] OK ATV1
OK
10.21.3Defined values
Parameter Type Description
<value> Number
0: DCE transmits limited headers, trailers and numeric text
1 (default and the factory-programmed value): DCE transmits full headers, trailers
and verbose response text
10.22Result code selection and call progress monitoring
control X
X
Modules All products
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full Yes No No - +CME Error
10.22.1Description
In a CS data call, determines how the DCE transmits to the DTE the CONNECT result code.
10.22.2Syntax
Type Syntax Response Example
Set ATX[<value>] OK ATX1
OK
10.22.3Defined values
Parameter Type Description
<value> Number
0: CONNECT result code is given upon entering online data state;
1-4: CONNECT <speed> result code is given upon entering online data state; (4 is
the default and the factory-programmed value)
<speed> Number Transfer speed for CSD calls configured via the CBST command