User Manual

Table Of Contents
SARA-R4 series-AT commands manual
UBX-17003787 - R16
10V24 control and V25ter
Page 115 of 401
10.18.2Syntax
Type Syntax Response Example
Set ATS12=<value> OK ATS12=80
OK
Read ATS12? <value>
OK
050
OK
10.18.3Defined values
Parameter Type Description
<value> Number Range 0 - 255. The answer to the read command is in "xxx" format. The default value
is 50 (1 s)
10.18.4Notes
SARA-R4 / SARA-N4
The command has no effect.
10.19Command echo E
E
Modules All products
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full No NVM No - +CME Error
10.19.1Description
Controls whether or not the MT echoes characters received from the DTE during command state.
10.19.2Syntax
Type Syntax Response Example
Set ATE[<value>] OK ATE1
OK
10.19.3Defined values
Parameter Type Description
<value> Number
0: echo off
1 (default and the factory-programmed value): echo on
10.20Result code suppression Q
Q
Modules All products
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
full No No No - +CME Error
10.20.1Description
Determines if DCE transmits result codes to the DTE or not. When result codes are being suppressed,
no portion of any intermediate, final or URC is transmitted. Information text transmitted in response to
commands is not affected by this setting.
10.20.2Syntax
Type Syntax Response Example
Set ATQ[<value>] OK ATQ1
OK