User Manual

Table Of Contents
SARA-R4 series-AT commands manual
UBX-17003787 - R16
10V24 control and V25ter
Page 114 of 401
10.16.3Defined values
Parameter Type Description
<value> Number Range 0 - 255. The answer to the read command is in "xxx" format. The default value
is 2.
10.17Automatic disconnect delay S10
S10
Modules All products
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
partial Yes No No - +CME Error
10.17.1Description
Specifies the time in tenth of a second, that the DCE will remain connected to the line after the DCE has
indicated the absence of received line signal. Not supported for GSM but the OK response is returned.
10.17.2Syntax
Type Syntax Response Example
Set ATS10=<value> OK ATS10=30
OK
Read ATS10? <value>
OK
030
OK
10.17.3Defined values
Parameter Type Description
<value> Number Range 1 - 254. Default: 1
10.17.4Notes
SARA-R4 / SARA-N4
The command has no effect.
10.18Escape prompt delay (EPD) S12
S12
Modules All products
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
partial Yes No No - +CME Error
10.18.1Description
Defines the maximum period, in fiftieths of a second, allowed between the reception of the last character of
the sequence of three escape characters from the DTE and the sending of the OK result code to the DTE. If any
characters are detected during this time, the OK will not be sent.
Furthermore, the timeout is:
The minimum period, before the first character reception of the three escape character sequence, during
which no other character must be detected to accept it as a valid first character
The maximum period allowed between receipt of first, or second, character of the three escape character
sequence and receipt of the next
The minimum period, after the last character reception of the three escape character sequence, during
which no other character must be detected to accept the escape sequence as a valid one