Page 113 of 401
Type Syntax Response Example
Read ATS6? <value>
OK
002
OK
10.14.3Defined values
Parameter Type Description
<value> Number Range 2 - 10. The answer to the read command is in "xxx" format. The default value is
2 s.
10.15Connection completion timeout S7
S7
Modules All products
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
partial Yes No No - +CME Error
10.15.1Description
Specifies the time in seconds, that the DCE shall allow between either answering a call or completion of dialling
and establishment of a connection with a remote site.
SARA-R4 / SARA-N4
The command has no effect.
10.15.2Syntax
Type Syntax Response Example
Set ATS7=<value> OK ATS7=30
OK
Read ATS7? <value>
OK
060
OK
10.15.3Defined values
Parameter Type Description
<value> Number Range 1 - 255. The answer to the read command is in "xxx" format.
SARA-R4 / SARA-N4 -The factory-programmed value is 0
10.16Command dial modifier time S8
S8
Modules All products
Syntax PIN required Settings saved Can be aborted Response time Error referenceAttributes
partial Yes No No - +CME Error
10.16.1Description
Specifies the amount of time, in seconds, that the DCE shall pause during dialling, when a ',' (comma) dial
modifier is encountered in a dial string.
The command has no effect.
10.16.2Syntax
Type Syntax Response Example
Set ATS8=<value> OK ATS8=4
OK
Read ATS8? <value>
OK
002
OK